ACL





 

 

 

 

 

ACL

Digital Data Cable is the Critical Link!

Since the introduction of USITT DMX512 (1990) as the industry wide standard lighting control protocol, the versatility and complexity of control needs has increased radically.

It is now easily possible to rely on one lighting console to control an entire lighting system comprising of dimmers, color changers, moving lights and strobes.

It is equally possible that one single length of data cable is the critical link for the whole system, so doesn't it make sense to ensure that you are using the best data cable available?

The sleeving of all TOUR-PLEX DATA-SURE cables contains a propriety compound that gives the cable a unique flame-retardant quality.

This compound also toughens the jacket giving the cable better resistance to damage caused in everyday use. TOUR-PLEX DATA-SURE cables are manufactured and tested to exacting specifications to ensure high performance and consistency.

All TOUR-PLEX DATA-SURE cables are factory-tested for Hi-Pot, Continuity, Impedance and Capacitance ensuring that you won't find a better data cable to be the critical link for your show.

Don't accept anything less!

 

 

 

 

 

ACL





 

 

 

 

 

ACL

TourNet Road-Worthy CAT-5e

All diagrams are representational and are not to scale



Description: 4 Pair Unshielded Twisted Pair Cable, 24 AWG Stranded Tinned Copper. Polyolefin Insulated .030" Industrial grade Jacket. U.S. Patents 5,606,151 and 5,734,126 and 5,763,823
Applications: High Flexibility, RJ-45 Compatible for either T568a or T568B Configurations. Design minimizes changes in electrical characteristics due to bending and kinking associated with patch cables.
Cores:

24 AWG Tinned soft annealed copper stranded
Nominal capacitance @ 1khz: 15pF/ft
Max Operating Voltage: 300V RMS
Color coded:
Blu+Blu/Wht, Org+Org/Wht, Grn+Grn/Wht, Brn+Brn/Wht

Physical Characteristics:

Installation Temparature: -25° C TO 75° C
Operating Temparature: -40° C TO 75° C
Insulating Material: Polyolefin
Max. Pulling Tension: 40 Lbs.
Min. Bend Radius: .25"
Jacket Material: PVC
Nominal Diameter: .245"

Weight Per 1000 FT: 27.0 lbs
Compliance: ISO/IEC 11801 CAT5E Patch, UL 1666 Riser, UL CMX Outdoor

 

 

ACL





 

 

 

 

 

ACL

Datasure 2

All diagrams are representational and are not to scale



Cores: 22 AWG (0.38mm²) tinned soft annealed copper stranded 19 × 34
Nominal capacitance conductor/conductor 20pF/ft
Color coded White/Black
Solid FR Polyethylene
Nominal thickness 0.009" (0.223mm)
Shielding: Aluminum Mylar providing 100% coverage
Tinned copper braid providing minimum 85% coverage
Nominal capacitance conductor/shield 40pF/ft
Nominal impedance 90 ohms
Fillers Strength Members: 2 Blue FR fibrillated Polypropylene fillers plus single Kevlar strength member
Outer Jacket: FR PVC Nominal thickness 0.030" (0.76mm) without paper separator
Overall cable diameter 0.180" (4.58mm)
Tensile strength 7000psi
Operating temperature range -30°C to +75°C
Conductivity per 1000ft 16ohms (max) at 20°C
Low temperature cold bend and impact tested 4hrs @ -50°C pass
Weight Per 100 Meter: 4 Kilos (8.88lbs)
Compliance: UL2919, UL VW1

 

 

ACL





 

 

 

 

 

ACL

Datasure 4

All diagrams are representational and are not to scale



Cores: 22 AWG (0.38mm&178;) tinned soft annealed copper stranded 19 × 34
Nominal capacitance conductor/conductor 20pF/ft
Color coded White/Black
2nd pair coded Red/Green
Solid FR Polyethylene
Nominal thickness 0.009" (0.223mm)
Shielding: Aluminum Mylar providing 100% coverage
Tinned copper braid providing minimum 85% coverage
Nominal capacitance conductor/shield 40pF/ft
Nominal impedance 90 ohms
Fillers Strength Members: 2 Blue FR fibrillated Polypropylene fillers plus single Kevlar strength member
Outer Jacket: FR PVC Nominal thickness 0.030" (0.76mm) without paper separator
Overall cable diameter 0.255" (6.48mm)
Tensile strength 6000psi
Operating temperature range -30°C to +75°C
Conductivity per 1000ft 16ohms (max) at 20°C
Low temperature cold bend and impact tested 4hrs @ -50°C pass
Weight Per 100 Meter: 5 Kilos (11.1lbs)
Compliance: UL2919, UL VW1

 

 

ACL




 

 

 

 

 

ACL

Digital Color Changer Cable

All diagrams are representational and are not to scale



Cores:

Data Pair:- 22AWG (0.38mm²) tinned soft annealed copper stranded 19 × 34.
Drain Wire:- 24 SWG (0.23mm²) tinned soft annealed copper stranded 7 × 32
Power:- 14 AWG (2.1mm²) bare soft copper stranded 41 × 30
Nominal capacitance conductor/conductor 13pF/ft
Data Pair:
- Color coded Green/Red Foam FR Polyethylene
Nominal thickness 0.010" (0.26mm)
Power:- Color coded Black/White
PR PVC Nominal thickness 0.016" (0.41mm)

Shielding: Data Pair:- Aluminum Mylar providing 100% coverage
Nominal capacitance conductor/shield 26pF/ft
Nominal impedance data pair 90ohms
Fillers Strength Members: 3 Blue FR fibrillated Polypropylene fillers plus clear Mylar binder
Outer Jacket: FR PVC Nominal thickness 0.035" (0.89mm) without paper separator
Overall cable diameter 0.290" (7.31mm)
Tensile strength 7000psi
Operating temperature range -30°C to +75°C
Conductivity per 1000ft 16ohms (max) at 20°C
Low temperature cold bend and impact tested 4hrs @ -50°C pass
Weight Per 100 Meter: 8 Kilos (17.76lbs)
Compliance: UL VW1

 

 

ACL




 

 

 

 

 